Rocom Healthcare Profile — Normative Specification v0.1

Contents

Rocom Healthcare Profile — Normative Specification v0.1

1. Scope

This profile defines the requirements a robot system MUST satisfy to be considered Rocom-conformant. It extends the VDA 5050 standard by adding healthcare-specific capability declarations, compliance event reporting, and chain-of-custody tracking on rocom/v0/ extension topics.

Rocom extensions use the separate rocom/v0/ namespace and never modify standard VDA 5050 messages.

1.1 Normative References

This profile is based on VDA 5050 version 2.1.0 (VDA 5050-2, published January 2025). All references to “VDA 5050” in this profile refer to this specific version unless explicitly stated otherwise.

VDA 5050 3.0 was published in April 2026 and introduces zones, movement rules, and areas requiring explicit permission. Rocom has reviewed these changes. Version 2.1.0 is retained as the normative baseline because it provides sufficient coverage for current deployments and is widely implemented. Overlap with 3.0 features (notably zone semantics) is addressed through Rocom’s own zone model (Part 1) and the Healthcare profile, rather than by depending on a newer VDA release.

The VDA 5050 specification and MQTT topic structure are publicly available: https://github.com/VDA5050/VDA5050

Topic namespace: vda5050/. Messages follow the VDA 5050 factsheet schema. Cancellation uses instantActions — the orchestrator publishes {"action": "cancelOrder", "order": {"serialNumber": "..."}} to vda5050/instantActions/<serialNumber>. Rocom extensions use the separate rocom/v0/ namespace and never modify standard VDA 5050 messages.

2. Conformance Levels

Levels follow Part 2 (L1 = Pilot, L2 = Single Site, L3 = Multi-Site). The Healthcare profile adds domain-specific requirements at every level.

Level 1 — VDA 5050 Baseline

The system SHALL: - [P-2.1.1] Publish a valid factsheet on vda5050/factsheet on connection. - [P-2.1.2] Publish periodic state updates on vda5050/state/<serialNumber>. - [P-2.1.3] Accept orders on vda5050/order/<serialNumber> and execute node sequences. - [P-2.1.4] Publish connection state on vda5050/connection/<serialNumber>. - [P-2.1.5] Support order cancellation via instantActions with cancelOrder as defined in VDA 5050 2.1 (topic: vda5050/instantActions/<serialNumber>).

Level 2 — Rocom Core

The system SHALL additionally: - [P-2.2.1] Publish compliance events on rocom/v0/compliance/event on every zone transition. - [P-2.2.2] Each compliance event MUST include auditCorrelationId referencing the orchestrator AuditEvent. - [P-2.2.3] Declare Rocom-profile capabilities on rocom/v0/capability/declare using keys from the capability registry. - [P-2.2.4] Report complianceStatus as passed, failed, or exception for each zone transition.

Level 3 — Multi-Site Transport

The system SHALL additionally: - [P-2.3.5] Support federated connection state: publish rocom/v0/connection/federated with cross-site routing information when operating across multiple deployment sites.

Healthcare Profile (any level)

When the Healthcare profile is declared, the system SHALL additionally: - [P-2.3.1] Publish chain-of-custody events on rocom/v0/chainOfCustody/event for tasks requiring chain-of-custody (chainOfCustody: true in capability params). - [P-2.3.2] Enforce restricted-zone access: robot MUST publish a restricted_zone_check compliance event before entering a restricted zone, and SHALL NOT proceed if complianceStatus is failed. - [P-2.3.3] Ensure chain-of-custody event completeness: every picked_up action MUST have a corresponding delivered or handed_off action within the task lifetime. - [P-2.3.4] Capability declarations MUST match a key defined in capability-registry.yaml. Undeclared keys SHALL cause a conformance test failure.

3. Capability Declaration

Every conformant robot SHALL publish a capability declaration containing: - key: one of the keys defined in the capability registry - level: basic, advanced, or certified - certified: boolean indicating whether the capability has passed certification testing

4. Audit Correlation

Every compliance and chain-of-custody event MUST carry an auditCorrelationId that references the corresponding orchestrator AuditEvent.eventId. This ensures the end-to-end audit trail from allocation decision through physical execution.

5. Restricted Zone Enforcement

When a task requires capability with restricted_zones: true: 1. The orchestrator SHALL include zone restriction constraints in the allocation proposal. 2. The gateway SHALL verify zone access before dispatching the order. 3. The robot SHALL publish a restricted_zone_check compliance event upon zone boundary crossing. 4. If access is denied, the robot SHALL NOT enter and SHALL transition to ERROR state.

6. Error Handling