Rocom — Part 2: Conformance

1. Conformance Levels

A system claiming Rocom conformance declares a level per Part. Levels are cumulative: a system at L2 satisfies all L1 requirements of that Part. Healthcare-specific requirements (chain of custody, restricted zone enforcement) may apply at any level — they are a profile dimension, not a level dimension.

Level Name Scope
L1 Pilot Minimal conformance for proof-of-concept and controlled evaluation.
L2 Single Site Full production readiness for a single deployment (hospital or municipality).
L3 Multi-Site Federated operations across multiple deployments; automatic lifecycle management.

1.1 Dimensions

Conformance has two independent dimensions:

  1. Level (L1–L3): scope of operational complexity — from pilot to multi-site federated operations.
  2. Profile (General / Healthcare): domain-specific requirements. The Healthcare profile adds chain-of-custody, restricted zone enforcement, and compliance event reporting. These requirements may be declared at any level.

A system declaring the Healthcare profile at L1 satisfies all L1 General requirements plus the Healthcare profile additions. This avoids the previous conflict where Part 5 treated Healthcare as L3-only.

2. Conformance Declaration

A conformant implementation MUST produce a Conformance Statement following the template below. The statement is a public document published by the implementer. The build_provenance section is mandatory: conformance claims must be reproducible against an identifiable build artifact, not against source code alone.

3. Conformance Statement Template


# Rocom Conformance Statement

# Implementer
implementer:
  organization: "TODO — organization name"
  product: "TODO — product name and version"
  contact: "TODO — email or URL for conformance inquiries"
  statement_date: "TODO — YYYY-MM-DD"

# Scope
conformance_scope:
  profile: "General"   # or "Healthcare"
  parts_declared:
    - part: 1
      level: L1   # or L2, L3
      status: conformant   # conformant / partial / not-tested
    - part: 2
      level: L1
      status: conformant
    - part: 3
      level: L1
      status: conformant
    - part: 4
      level: L1
      status: conformant
    - part: 5
      level: L1
      status: conformant
    - part: 6
      level: L1
      status: conformant
    - part: 7
      level: L1
      status: conformant

  # For each Part with status "partial", list non-conforming requirements:
  deviations:
    - part: 5
      requirement: "p-req-201"
      status: not-implemented
      rationale: "TODO — explanation"
      planned_resolution: "TODO — target date or edition"

# Build Provenance
# Conformance claims must be tied to an identifiable build. Source code
# alone does not constitute evidence: the compiled artifact, toolchain,
# and build environment must be reproducible for audit.
build_provenance:
  toolchain: "TODO — compiler/runtime and version (e.g., 'Ferrocene 26.02.0', 'rustc 1.75.0')"
  target: "TODO — compilation target triple (e.g., 'x86_64-unknown-linux-gnu')"
  build_command: "TODO — reproducible build command (e.g., 'cargo build --release')"
  artifact_hash: "TODO — SHA-256 of the compiled binary or test artifact"
  build_log_reference: "TODO — URL or path to the build log"

# Test Evidence
test_evidence:
  conformance_tests_executed:
    - test_id: "TODO — e.g., DG-01, ID-01"
      result: pass   # pass / fail / not-applicable
      notes: "TODO — test date, environment, any conditions"

# Certification (optional)
certification:
  certified_by: "TODO — certification body, or 'self-declared'"
  certificate_id: "TODO — certificate reference"
  valid_until: "TODO — YYYY-MM-DD"

4. Partial Conformance

Partial conformance is permitted. An implementer declaring partial conformance MUST:

  1. List every non-conforming requirement in the deviations section.
  2. Provide a rationale for each deviation.
  3. Indicate a planned resolution date or target edition.

Systems with more than three deviations at L2 or above are not eligible for Rocom Certified status.

5. Formal Certification

Formal Rocom Certified status is awarded by independent Certification Providers under ROCOM Board oversight upon successful execution of the full conformance test suite at the declared level and profile. The Certification Program is defined in Sup-005 (Certification Provider Requirements). During the transition period before providers are appointed, self-declaration of conformance remains available.

5.1 Deviation Severity

Declarations of partial conformance must classify each deviation:

Severity Definition Certification impact
Critical Security vulnerability, safety hazard, or data integrity failure Certification blocked. Must be resolved before certification.
Major Missing normative requirement that affects interoperability Maximum 1 major deviation permitted.
Minor Implementation difference that does not affect interoperability Maximum 2 minor deviations permitted.

Systems with more than three deviations total (any severity) at L2 or above are not eligible for Rocom Certified status. One or more Critical deviations block certification regardless of level.